本文已被:浏览 2844次 下载 2592次
投稿时间:2012-03-30 修订日期:2012-03-31 录用日期:2012-04-01 网络发布日期:2012-09-19
投稿时间:2012-03-30 修订日期:2012-03-31 录用日期:2012-04-01 网络发布日期:2012-09-19
中文摘要: 按1∶23的几何尺寸比例对生产用艾萨炉喷枪进行试验,得到渣层纵向高度、横向厚度变化以及进出水温度等数据,同时还对渣层稳态热传导过程进行了热平衡计算。结果表明,渣层纵向高度h与喷枪外壁温度t的关系为:367.668t 1972828.44=exp(20.196918-45.798h)。按照该式计算的渣层最顶端处喷枪外壁温度为912 ℃,与实际测得的908 ℃相符合,证明了艾萨炉喷枪渣层的热平衡计算是正确和合理的。
Abstract:The spray gun for ISA furnace was tested in accordance with 1∶23 real size scale. The datas of vertical height and horizontal thickness of slag, as well as the water temperature in and out were obtained. Meanwhile, the heat balance for steady-state heat conduction process of the slag was calculated. The results show that the relationship between vertical height (h) of slag layer and the outer wall temperature (t) of the spray gun is 367.668t 1972828.44=exp(20.196918-45.798h). According to this formula, the temperature of spray gun outer wall at the top of the slag layer is 912 ℃, which is correspond with the actual measurement of 908 ℃. The heat balance calculation is proved to be correct and reasonable.
keywords: ISA furnace spray gun slag layer heat balance calculation
文章编号: 中图分类号: 文献标志码:
基金项目:
| Author Name | Affiliation | |
| LI DONG | Facult of Metallurgical and Energy Engineering,Kunming University of Science and Technology | lidong2009202003@163.com |
| ZHU Yun | zhuyun202@sina.com |
引用文本:
李 东,朱 云.艾萨炉喷枪渣层的热平衡计算[J].有色金属(冶炼部分),2012(10):10-12.
LI DONG,ZHU Yun.Heat Balance Calculation of Slag Layer for ISA Furnace Spray Gun[J].Nonferrous Metals (Extractive Metallurgy),2012(10):10-12.
李 东,朱 云.艾萨炉喷枪渣层的热平衡计算[J].有色金属(冶炼部分),2012(10):10-12.
LI DONG,ZHU Yun.Heat Balance Calculation of Slag Layer for ISA Furnace Spray Gun[J].Nonferrous Metals (Extractive Metallurgy),2012(10):10-12.