本文已被:浏览 3715次 下载 63次
投稿时间:2011-03-04
投稿时间:2011-03-04
中文摘要: 以氧化铝生产溶出过程中的套管换热器为研究对象,采用工程分析方法对其换热过程进行了分析,得出了单套管、三套管、四套管三种不同套管的传热系数,并对其进行了比较。结果表明,相同的矿浆流量下三套管的换热效果较好。
Abstract:The casing tube heat exchanger in digestion process of alumina was studied, the heat transfer process was analyzed by means of engineering analysis and the heat transfer coefficients of three different casing tubes including single casing pipe, triple casing pipe and quadruple casing pipe were compared in digestion process of alumina. The results show that the triple-pipe gives the better heat transfer coefficient under the same slurry flow rate.
keywords: Alumina Digestion Casing tube Heat transfer coefficient
文章编号: 中图分类号: 文献标志码:
基金项目:国家重点基础研究发展计划项目(2007CB206903);国家自然科学基金资助项目(51036003)
引用文本:
刘莉娜,黄望梅,刘志春,陈德,阳志洪,刘伟.氧化铝溶出工艺中各种套管传热系数的比较[J].有色金属(冶炼部分),2011(10):17-19.
LIU Li-na,HUANG Wang-mei,LIU Zhi-chun,CHEN De,YANG Zhi-hong,LIU Wei.Heat Transfer Coefficient Comparison of Various Casing Tubes in Alumina Digestion Process[J].Nonferrous Metals (Extractive Metallurgy),2011(10):17-19.
刘莉娜,黄望梅,刘志春,陈德,阳志洪,刘伟.氧化铝溶出工艺中各种套管传热系数的比较[J].有色金属(冶炼部分),2011(10):17-19.
LIU Li-na,HUANG Wang-mei,LIU Zhi-chun,CHEN De,YANG Zhi-hong,LIU Wei.Heat Transfer Coefficient Comparison of Various Casing Tubes in Alumina Digestion Process[J].Nonferrous Metals (Extractive Metallurgy),2011(10):17-19.