中文摘要: 直接测定了铝电解质实际样品的初晶温度。根据分析结果拟合出该体系初晶温度与分子比数学模型。试验了不同材质的高温传感器及保护套管,石墨坩埚作盛样器,对其测温的准确度作了验证,并对其形状作了改进,使传感器的使用寿命得到了延长。
中文关键词: 传感器 初晶温度 分子比
Abstract:Liquidus temperature of actual aluminum electrolyte samples was measured directly. A mathematic model about the relationship between liquidus temperature and cryolite ratio was simulated. Sensors made of different materials and protection tubes were compared and the best combination of the sensor with the protection tube was selected. A new type of graphite crucible was preferred. The improvements lengthen the using time of sensors.
文章编号: 中图分类号:TF821 文献标志码:
基金项目:
引用文本:
任凤莲,练文柳,李向群.铝电解质初晶温度检测及其数模拟合的研究[J].有色金属(冶炼部分),2003(2):30-32.
.Research on Determination and Modeling of Liquidus Temperature of Aluminum Bath[J].Nonferrous Metals (Extractive Metallurgy),2003(2):30-32.
任凤莲,练文柳,李向群.铝电解质初晶温度检测及其数模拟合的研究[J].有色金属(冶炼部分),2003(2):30-32.
.Research on Determination and Modeling of Liquidus Temperature of Aluminum Bath[J].Nonferrous Metals (Extractive Metallurgy),2003(2):30-32.